Capacity DC220
Fully variable 0.6A to 210A at 30-50V DC. Max 10.5kW.
Sections of 0.6 to 5, 5, 10, 20 and 5 x 30A
@ 45V - 210A with all sections connected
Controls
Fixed sections: 9 toggle switches
Variable section: knob to control graded rheostat
Fuse: 1
Resistor Elements
Expanded mesh and mica card elements wound with high-grade nickel-chrome stainless steel resistance elements.
Cooling
Fan cooled by four 30-50 VDC fans, taking their supply from the test load. Overtemperature protection. Insulating voltage 750 V.
Ammeter shunt
Rating: 100A = 100mV
Input cables and connectors
Two 2.5m, 50mm2 flexible input cables complete with M12 lugs and quick-release connectors.
Metering circuit: 4mm banana socket.
Case
Blue aluminium case with mesh over air ducts on 4 omni-directional braked castors.
Carrying handle. Ingress protection IP 20. With instructions and warning labels.
Dimensions: 540 x 280 x 490mm high Weight: 10kg complete